FAQ
- Powder Measuring Instrument -

Powder Measuring Instrument General

What is the difference between specific dust and general dust?

Dust that may pose a health hazard to the human body is called specified dust, and dust that does not pose a threat to human health is called general dust.

Specific dust: asbestos, sulfur oxide, lead powder, cadmium etc.

General dust: cement powder, lime powder, iron powder etc.

Air Particle Monitor

Where and how to install the Air Particle Monitor.
Please install it in a place where you are concerned about the generation of fine particles. You can use it by installing it on the wall or desk. To fix it, use M3 screw mounting holes.
What is the service life of an Air Particle Monitor?

About 5 years.

When using a typical monitor for a long time, the laser output decreases and the photosensor's light reception sensitivity decreases, but ours is equipped with an auto-calibration function, so you can use it for a relatively long time.

As a result, the service life is approximately 5 years.

Is maintenance required for Air Particle Monitor?

It has an auto-calibration function, so no routine maintenance is required. However, please be careful not to allow dust to accumulate on this product.
What is the power specifications of Air Particle Monitor?

Powered by DC24V.

You can also connect it to an outlet using the optional AC adapter.  Further, if installed inside a panel, it can be operated by supplying 24VDC directly to the terminal block from a switching power supply etc.

Can Air Particle Monitor be used in a clean room?
The Conditions vary depending on the cleanliness required for the clean room. We recommend using this product in cleanliness class 10,000 (ISO standard class 7) or higher.

Dust Monitor

Does the Dust Monitor require calibration?  When should it be done?

Instead of calibration, the normality needs to be confirmed.

In order to use the product with reliability, we recommend checking its normality at least once a year. There are two methods: either we dispatch a field engineer or the customer returns the equipment for us to check it at our factory.   In either case, advance notice is required.   Please feel free to contact us.

How is the Dust Monitor installed to the duct?
Drill a hole in the duct and weld the attached G1 socket. You can install the dust monitor by screwing it into the socket.  Make sure to ground it.
The exhaust gas to be measured contains moisture.   Will it influence the measurement?

Yes, it does.

Our Dust Monitor and Air Dust Monitor uses a triboelectric method and we recommend to use them at humidity 40% or less.  If the humidity is high, the essential static electricity will not be generated when there is friction and the product will not function.  Additionally, if steam adheres to the probe and condenses, it will cause dust to adhere and electrodes to short-circuit, making it impossible to take accurate measurements. 

Although we do not handle it, in the case of an optical type, if steam is generated, the light will scatter or it adhere to the lens, making accurate measurements impossible.  It can also cause dust to adhere, causing drift and displaying high values.

Are there any restrictions such as pipe diameter, flow velocity, pressure resistance etc. when installing Dust Monitor?

Although the pipe diameter is not specified, the length of the detection probe is Max.1m. 

Although there is no max. flow velocity, we have an experience of 30 m/s.

The pressure resistance is Max. 200kPa.  But the humidity must be below 40%.

How should I decide the length of the dust monitor probe?

The probe length varies depending on the pipe diameter and flow velocity, but should be approximately 1/2 to 1/3 of the actual pipe diameter.  For example, if the pipe diameter is 2m, the length will be 0.6m to 1m.  However the maximum probe length is 1m.

Air Dust Monitor

What is the maintenance of Air Dust Monitor?

If the probe becomes dirty, turn off the power, remove the sensor from the self-suction device and wipe the probe with a wet cloth.  Easy maintenance is realized.

  *Be sure to connect the equipment's ground wire during maintenance.

  *Working with bare hands may short-circuit the equipment and cause it to malfunction.

    Workers must always wear insulated gloves.


>>Please go to "Product page" for details.

The exhaust gas to be measured contains moisture.  Will it influence the measurements?

Yes, it does.

Our Dust Monitor and Air Dust Monitor uses a triboelectric method and we recommend to use them at humidity 40% or less.  If the humidity is high, the essential static electricity will not be generated when there is friction and the product will not function.  Additionally, if steam adheres to the probe and condenses, it will cause dust to adhere and electrodes to short-circuit, making it impossible to take accurate measurements. 

Although we do not handle it, in the case of an optical type, if steam is generated, the light will scatter or it adhere to the lens, making accurate measurements impossible.  It can also cause dust to adhere, causing drift and displaying high values.

Can Air Dust Monitor be used even in heavy rain?

The protection structure is IP65 and it can be used outdoors.

If water drops of rain etc. enter the inside of the measurement duct, the measured value may increase. Also, since it is self-suctioning, mist components will also be suctioned.  At this time, the measured value may also increase.

Please prepare a roof etc. if required.

Can I see the signal measured by Air Dust Monitor on my PC or smartphone?
The separate type that is battery-powered and have wireless connectivity can output via LAN, so you can check signals and alarms on your PC or smartphone.

What is the measurable area of Air Dust Monitor?

The range that the device can collect is approximately 10 cm from the air intake.  Please install it at a point where you are concerned about dust leakage. Further the intake port can be used by changing its direction according to the environment.

Dust Switch

What is the detectable concentration range of Dust Switch?

Measurement is possible at dust concentrations of 0.1 to 1000 mg/m3.

Is it possible to change the probe length of Dust Switch?
The change of probe length is not available.
What is Dust Switch used for?
It is installed at the exhaust port of a small dust collector and used to detect breakage of  the bag filter (filter cloth).
What is the min. detection sensitivity of Dust Switch?
10mg/m3 (based on talc)